Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38639844

RESUMO

The escalating rates of rape and sexual assault cases underscore the essential need to analyze associative evidence of sexual assault to ensure justice. The condom, when used during the act of sexual assault/rape, leaves behind traces of lubricant that could be instrumental in establishing the link between the victim and perpetrator. This leading evidence is crucial especially when the traditional DNA analysis is challenging owing to the lack of biological evidence. The present study employs the use of ATR FTIR spectroscopy coupled with the chemometric, to discern the chemical discrimination of condom lubricants. The study also aimed to investigate simulated real-case scenarios by analysing the effect of different matrices such as vaginal fluid, menstrual blood, and undergarment substrates (cotton, polyester and nylon) on condom traces. The difference in the spectral profile of pre-coitus and post-coitus samples was also investigated. The results of the present study are noteworthy, unveiling the efficacy of discriminating the condom lubricants of different brands and other frequently used household lubricants with 100% sensitivity, specificity, and accuracy. Condom lubricants are detected despite the presence of contaminants such as menstrual blood, and vaginal fluid, across different substrates and, in post-coital conditions. In conclusion, this study presents a comprehensive approach to analysing condom lubricants, offering a potential breakthrough in the investigation of sexual assault cases, coupled with the ability to counter false accusations.

2.
Forensic Sci Int ; 357: 111988, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38520829

RESUMO

In recent years, collection and analysis of condom evidence in sexual assault investigations are becoming more common in forensic caseworks. Condom analysis can provide investigative leads or establish potential contact between the suspect and victim in the absence of DNA evidence or supplement biological evidence. Recent forensic literature shows significant advancements in the analysis of condom lubricants, including casework samples. There is an increasing trend in the use of chemometric tools for the comparison and interpretation of the results. This review highlights the advances in common analytical techniques used for the analysis of condom lubricants with a particular focus on the developments occurring in recent years, including chemometric interpretation. The analysis of reference and casework samples (swab samples, samples on skin, clothing and fingermark) are discussed separately. For casework samples, the transfer and persistence of different lubricant formulations are discussed, along with their detection with various analytical approaches. The issues with the interpretation of lubricants are also discussed in another section, with particular emphasis on samples such as personal hygiene products which have similar formulations with sexual lubricants and the interpretation of negative profiles. The current challenges in the field and prospects for future research are also discussed.


Assuntos
Medicina Legal , Delitos Sexuais , Medicina Legal/métodos , Preservativos , Lubrificantes/análise , Pele/química
3.
J Forensic Sci ; 68(6): 1982-1990, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37606297

RESUMO

Sealing wax is used for maintaining the integrity and authenticity of a document or physical evidence. Any tampering with the seal calls into question the overall integrity and authenticity of the tangible evidence or document. In these circumstances, determining the authenticity of the sealing material (physical and chemical) becomes imperative. In this study, ATR-FTIR spectroscopy supported by chemometrics has been used to differentiate sealing wax samples belonging to 12 different brands available across India. All the samples were first melted, cooled, and then analyzed using ATR-FTIR spectroscopy in the mid-infrared region (4000-600 cm-1 ). The obtained spectra were first examined visually for the presence of different functional groups. Principal component analysis (PCA) and principal component analysis-linear discriminant analysis (PCA-LDA) were employed to analyze the sample clustering patterns and to categorize them into their respective groups, respectively. For classification, a PCA-LDA training model was applied, and it demonstrated 95.83% accuracy. The validation test resulted in an accuracy of 83.33%. PCA-LDA model offered 100% accurate prediction for samples on various substrates, including cloth, cardboard, and paper. A blind study was also performed using five unknown samples, which were accurately classified into their respective groups. PCA-LDA model will be helpful in providing investigative leads by linking a questioned sealing wax sample with its respective group.

4.
J Forensic Sci ; 68(6): 1972-1981, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37417337

RESUMO

Lip balm may be encountered as physical evidence in cases involving sexual assaults, homicides, and kidnappings. Lip balm can be used as corroborative evidence by providing a potential link between the victim, accused, and the crime scene. For lip balms to be used as evidence, it is important to understand the diversity and their aging process under different conditions. Therefore, in this study, ATR-FTIR spectroscopy in conjunction with chemometric tools such as principal component analysis (PCA) and linear discriminant analysis (LDA) has been used for the objective identification and differentiation of 20 brands of lip balms. Moreover, lip balms on different substrates and wearing effects over time were also investigated. The results show that the PCA-LDA training accuracy was 92.5%, whereas the validation accuracy comes out to be 83.33%. A blind study using pristine samples was also performed which resulted in 80% PCA-LDA accuracy. PCA-LDA prediction of samples on various substrates showed a higher chemometric prediction accuracy for nonporous substrates (glass, plastic, and steel), than for porous substrates (cotton cloth, cotton swab stick, dry tissue paper, and white paper) for samples kept in room temperature and under sunlight for 15 days. The substrate study showed that the samples from various substrates could effectively generate respective spectra which can help in brand-level identification even after several days. The present method demonstrates a potential for lip balm samples to be used in forensic casework applications.


Assuntos
Medicina Legal , Lábio , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Análise Discriminante , Análise de Componente Principal , Homicídio
5.
J Forensic Sci ; 67(3): 911-926, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35103307

RESUMO

Electrical tapes are recovered during criminal investigations as physical evidence in cases of rape, kidnapping, and explosion incidents. The analysis of such evidence can provide an evidentiary link between the suspect, the victim, object, or the crime scene. In the present study, 25 brands of electrical tapes have been analyzed using ATR-FTIR (attenuated total reflectance Fourier transform infrared) spectroscopy. Samples (1 cm2 ) were analyzed in the mid IR (Infrared) region from 4000-600 cm-1 , and the functional groups of various components have been profiled. Chemometric methods-PCA (principal component analysis) and PCA-LDA (linear discriminant analysis) have been employed to interpret the data and classify the samples into its respective classes. Preliminary assessment of sample clustering due to similar chemical composition was visualized using PCA. PCA-LDA applied for classification purpose yielded classification accuracy (calibration) of 92.98% for the adhesive side and 88% for the backing side. The validation results showed classification accuracy of 89.47% for the adhesive side and 84% for the backing side. Blind validation study was carried out using 5 samples, and classification accuracy of 100% and 80% was obtained for the adhesive and the backing side, respectively. In the current study, a preliminary substrate study was carried out, and the results showed that the backing samples could be more accurately matched to their correct source of origin than the adhesive side.


Assuntos
Quimiometria , Análise Discriminante , Análise de Fourier , Análise de Componente Principal , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...